Eight-Well Groundwater Purging and Sampling Record

Page two of this article is a groundwater well purging and sampling form that can be used to record indicator parameters pH, conductivity, temperature, etc., taken during purging of a groundwater monitoring well.   The form is very concise and allows the data from eight wells to be recorded on one sheet of paper.
 
—   Modify Form for Use by Your Company
 
The form is not copyrighted. You may modify it using WORD to display your company name, address, and telephone numbers and the particular indicator parameters you measure when purging your groundwater monitoring wells.
 
—   Calculation of Five Well Casing Volumes
 
The form provides a simple way to calculate the five well casing volumes 5CV that must be pumped if pumping is continued because the indicator parameters don"t stabilize or the well does not run dry. As indicated on the form, the monitoring well depth Depth(a) in feet is recorded, the groundwater level depth WL(b) in feet is measured, and height of the water column in the well WC(a-b) is calculated by subtracting the groundwater level depth WL(b) from the monitoring well depth Depth(a). The volume of five well casing volumes 5CV is calculated by multiplying the height of the water column, WC(a-b), by a factor 0.816 gallons per foot for a 2- well and by a factor of 3.26 for a 4- well. For example, if Depth(a) is 20 feet and WL(b) is 6.51 feet, WC(a-b) is 13.49 feet. For a 2- well, 5CV is 13.49 x 0.816 = 11.00 gallons.   
 
—   Calculate Cumulative Volume Increment at Which to Measure Indicator Parameters
 
The Gal column on the form is used to record the cumulative gallons of equal volume increments at which the indicator parameters are measured. To make sure you don"t run past the recording lines before five casing volumes are pumped, the minimum volume increment is calculated by dividing 5CV by eight, the number of lines on the form. For example if 5CV = 11 gallons, the minimum volume increment is 1.4 gallons so as not to outrun the form. In practice this would be rounded up to an easily measured volume such as 1.5 gallons.
 
—   Cumulative Volume Increment Must Be At Least Twice the Flow Cell Volume
 
To obtain representative values of the indictor parameters, water in the flow cell containing the indicator parameter meters must be replaced by freshly pumped water between readings. To make sure this occurs, the cumulative volume increment must be at least twice the volume of the flow cell. The choice of an incremental volume of 1.5 gallons requires that the volume of the flow cell be no more than 3 quarts, which is quite large for a flow cell.

By Don McEdwards